Technical data:


Model

SCH-AWM6DC

Power supply

220~240V,50Hz

Heating(air+7℃/water35℃)

Capacity

KW

6.5

Heating water capacity

KW

1.45

Rated current

A

6.59

COP

W/W

4.48

Heating(air+2℃/water35℃)

Capacity

KW

6.1

Heating water capacity

KW

1.63

Rated current

A

7.43

COP

W/W

3.73

Heating(air-7℃/water35℃)

Capacity

KW

5.8

Heating water capacity

KW

1.91

Rated current

A

8.70

COP

W/W

3.03

Heating(air+7℃/water45℃)

Capacity

KW

5.80

Heating water    capacity

KW

1.73

Rated current

A

7.86

COP

W/W

3.35

Heating(air+2℃/water45℃)

Capacity

KW

5.6

Heating water capacity

KW

1.86

Rated current

A

8.08

COP

W/W

3.01

Heating(air+15℃/water45℃)

Capacity

KW

8.30

Heating water    capacity

KW

1.92

Rated current

A

8.73

COP

W/W

4.32

Heating(air-7℃/water45℃)

Capacity

KW

5.3

Heating water capacity

KW

2.07

Rated current

A

9.44

COP

W/W

2.55

Heating(air+20℃/water55℃)

Capacity

KW

8.20

Heating water    capacity

KW

2.12

Rated current

A

9.68

COP

W/W

3.85

Heating(air7℃/water55℃)

Capacity

KW

5.25

Heating water    capacity

KW

1.82

Rated current

A

8.28

COP

W/W

2.88

Heating(air2℃/water55℃)

Capacity

KW

4.85

Heating water    capacity

KW

2.03

Rated current

A

9.26

COP

W/W

2.38

Heating(air-15℃/water55℃)

Capacity

KW

3.80

Heating water capacity

KW

2.26

Rated current

A

10.20

COP

W/W

1.68

Cooling(air35℃/water18℃)

Capacity

KW

8.50

Input

KW

2.30

Rated current

A

10.49

EER

W/W

3.68

Cooling(air35℃/water7℃)

Capacity

KW

6.00

Input

KW

1.91

Rated current

A

8.68

EER

W/W

3.14

Electric heating

KW

3

current

A

13.6

water pump

Input (L/M/H)

W

55/70/100

Rated current

A

55/70/100

Outdoor unit

Dimension

mm

1105*855*393

Packing

mm

1135*750*460

Net/Gross weight

kg

85/88

Outdoor air flow

m3/h

2500

(water)flow rate

m3/h

1.05

Design pressure

MPa

4.2

Refrigerant

 

R410a

Heating water range

20 - 60℃

Cooling water range

5  - 31℃

Compressor Type

 

GMCC\Panasonic

Ambient temp

-25 ℃ - 43℃

Noise level(1 M)

dB(A)

≦52.0



Why choose Deron Heat Pump:

---Energy efficient
Reduce energy cost and greenhouse gas emission.

---Safety

Water and electricity isolation technology and comprehensive protection, like anti-freezing protection, water flow protection, high/low pressure protection, phase sequence protection etc.

--- Convenience and economic

Modern heat pump water heaters, replacing for solar panels and electric/gas water heaters.
Can be installed where solar roof collectors aren't suitable and looks better.
Less electricity and running cost, an ideal upgrade from the traditional water heaters.

---Strict quality control
ISO industry standards.
Standard &strict manufacturing process.
Every product must be tested and double checked before package.
---Eligible for trade and distribution
CE, CB, CCC, WATERMARK, SAA, AUSTRALIA STANDARD, etc.
---Customer orientation
DERON provide you optimized solutions and product customization as well as globalized customer services.
--- Satisfaction guarantee

18 months warranty for air-to-water heat pumps and water-to-water heat pumps, and 24 months special for swimming pool heat pumps.


Hot Tags: high cop DC inverter heat pump, China, suppliers, manufacturers, factory, customized, quotation, low price, made in China
Related Products
Feedback