Household heat pump is with smaller heating capacity;

Inverter heat pump mainly with inverter type circulation water pump, fan motor and compressor;

This integrated kind of heat pump is easier to installed;

Still be work under ambient temp. minus 25 degree C;


Technical data:

Model

SCH-AWM9DC

Power supply

220~240V,50Hz

Heating(air+7℃/water35℃)

Capacity

KW

9.0

Heating water capacity

KW

2.00

Rated current

A

9.09

COP

W/W

4.50

Heating(air+2℃/water35℃)

Capacity

KW

8.8

Heating water capacity

KW

2.34

Rated current

A

10.66

COP

W/W

3.75

Heating(air-7℃/water35℃)

Capacity

KW

8.2

Heating water capacity

KW

2.71

Rated current

A

12.34

COP

W/W

3.02

Heating(air+7℃/water45℃)

Capacity

KW

8.40

Heating water    capacity

KW

2.50

Rated current

A

11.36

COP

W/W

3.36

Heating(air+2℃/water45℃)

Capacity

KW

8.05

Heating water capacity

KW

2.66

Rated current

A

11.58

COP

W/W

3.02

Heating(air+15℃/water45℃)

Capacity

KW

11.00

Heating water capacity

KW

2.52

Rated current

A

11.49

COP

W/W

4.35

Heating(air-7℃/water45℃)

Capacity

KW

7.6

Heating water capacity

KW

2.95

Rated current

A

13.44

COP

W/W

2.57

Heating(air+20℃/water55℃)

Capacity

KW

10.50

Heating water    capacity

KW

2.72

Rated current

A

12.36

COP

W/W

3.86

  Heating(air7℃/water55℃)

Capacity

KW

8.00

Heating water    capacity

KW

2.76

Rated current

A

12.58

COP

W/W

2.89

  Heating(air2℃/water55℃)

Capacity

KW

7.60

Heating water    capacity

KW

3.19

Rated current

A

13.88

COP

W/W

2.38

Heating(air-15℃/water55℃)

Capacity

KW

5.90

Heating water capacity

KW

3.47

Rated current

A

15.77

COP

W/W

1.70

 Cooling(air35℃/water18℃)

Capacity         

KW

10.90

Input

KW

2.93

Rated current

A

13.35

EER

W/W

3.71

   Cooling(air35℃/water7℃)

Capacity         

KW

8.5

Input

KW

2.69

Rated current

A

12.26

EER

W/W

3.15

Electric heating

KW

3

current

A

13.6

water pump

Input (L/M/H)

W

55/70/100

Rated current

A

55/70/100

Outdoor unit

Dimension

mm

1105*855*393

Packing

mm

1125*1004*460

Net/Gross weight

kg

95/101

Outdoor air flow 

m3/h

2800

(water)flow rate

m3/h

1.6

Design pressure       

MPa

4.2

Refrigerant

 

R410a

Heating water range     

20 - 60℃

Cooling water range        

5  - 31℃

Compressor Type

 

GMCC\Panasonic

Ambient temp   

-25 ℃ - 43℃

Noise level(1 M)

dB(A)

≦53.0


There are three laboratories in DERON’s factory.

International heat pump lab..jpg


First lab,Air source/water source/ground source comprehensive lab

(General lab for heat pump unit)

This lab is built to meet national standards and accredited under TUV.

Under stimulant ambient temperature form -20℃ to 45℃, the lab is applied to test water source and ground source heat pump unit for hot water & heating /cooling.

Moreover, it is built for testing heat pump unit of the power input ranging from 0.8kw to 36kw, as well as the frequency from 50Hz to 60Hz.

Second lab, Air source /water source /ground source comprehensive lab for large units

(Special low ambient lab for large units)

This lab is built to meet international standards.

The lab is used for B&W (Germany Company) - Deron co-operating experiment and also used by Chinese Academy of Sciences.

Under stimulant ambient temperature from -30℃ to 45℃ , the lab is applied to test water source heat pump at the heating capacity of 154kw, water/ground source unit at the heating capacity of 1440kw, and EMS heat pump unit for large units especially.

Moreover, it is built for testing heat pump unit of the power input ranging from 0.8kw

to 36kw as well as the frequency from 50Hz to 60Hz.

Third lab, Hot water & heating /cooling enthalpy lab

(Special lab for DR Series Heat Pump with multi-function)

This lab is built to national standards, under stimulant ambient temperature from -10℃ to 45℃, the lab is applied to test hot water& heating/cooling heat pump unit,especially these units of power input from 0.8kw to 18.4kw.

Moreover, it is built for testing heat pump unit of the frequency ranging from 50Hz to

60Hz.

TUV certificated DERON labs.jpg

DERON’s labs have been certificated by TUV.


Hot Tags: residential DC inverter heat pump, China, suppliers, manufacturers, factory, customized, quotation, low price, made in China
Related Products
Feedback