Split Type Inverter Heat Pump

Home > Product > Inverter Heat Pump > Split Type inverter Heat Pump

New Looking Inverter Heat Pump

New Looking Inverter Heat Pump

New arrival inverter heat pump with good looking; Air to water Deron brand heat pump water heater with evi technology; DC inverter water heater is more efficient than on off type; High defrosting efficiency; Operating ambient temp ranged from -25 to 43 degree C; OEM/ ODM order is available;...

Chat Now
Product Details

New arrival inverter heat pump with good looking;

Air to water Deron brand heat pump water heater with evi technology;

DC inverter water heater is more efficient than on off type;

High defrosting efficiency;

Operating ambient temp ranged from -25 to 43 degree C;

OEM/ ODM order is available;


Technical data:

Model

SCH-AWS15DC

Power supply

1,220~240V,50Hz

3,  380~415V,50Hz

Heating(air+7℃/water35℃)

Capacity

KW

15.0

Heating water capacity

KW

3.31

Rated current

A

14.42/5.04

COP

W/W

4.52

Heating(air+2℃/water35℃)

Capacity

KW

14.5

Heating water capacity

KW

3.86

Rated current

A

16.87/5.86

COP

W/W

3.75

Heating(air-7℃/water35℃)

Capacity

KW

14.0

Heating water capacity

KW

4.65

Rated current

A

21.14/7.06

COP

W/W

3.01

Heating(air+7℃/water45℃)

Capacity

KW

14.50

Heating water    capacity

KW

4.25

Rated current

A

18.51/6.18

COP

W/W

3.41

Heating(air+2℃/water45℃)

Capacity

KW

14.00

Heating water capacity

KW

4.62

Rated current

A

20.08/7.01

COP

W/W

3.03

Heating(air+15℃/water45℃)

Capacity

KW

17.50

Heating water    capacity

KW

4.02

Rated current

A

17.47/6.10

COP

W/W

4.35

Heating(air-7℃/water45℃)

Capacity

KW

13.10

Heating water capacity

KW

5.05

Rated current

A

21.99/7.67

COP

W/W

2.59

Heating(air+20℃/water55℃)

Capacity

KW

16.80

Heating water    capacity

KW

4.35

Rated current

A

18.92/6.61

COP

W/W

3.86

  Heating(air7℃/water55℃)

Capacity

KW

14.10

Heating water    capacity

KW

4.89

Rated current

A

21.14/7.06

COP

W/W

2.88

  Heating(air2℃/water55℃)

Capacity

KW

13.00

Heating water    capacity

KW

5.43

Rated current

A

23.64/8.25

COP

W/W

2.39

Heating(air-15℃/water55℃)

Capacity

KW

9.30

Heating water capacity

KW

5.53

Rated current

A

24.16/8.40

COP

W/W

1.68

 Cooling(air35℃/water18℃)

Capacity         

KW

17.90

Input

KW

4.86

Rated current

A

22.10/7.38

EER

W/W

3.68

   Cooling(air35℃/water7℃)

Capacity         

KW

12.0

Input

KW

3.79

Rated current

A

17.2/5.75

EER

W/W

3.16

Electric heating

KW

3

current

A

13.6

water pump

Input (L/M/H)

W

135/190/245

Rated current

A

135/190/245

Outdoor unit

Dimension

mm

940*375*1340

Packing

mm

1000*415*1400

Net/Gross weight

kg

105.5/123

Indoor unit

Dimension

mm

485*350*690

Packing

mm

560*340*790

Net/Gross weight

kg

44/47

Outdoor air flow 

m3/h

5600

(water)flow rate

m3/h

2.6

Design pressure       

MPa

4.2

Refrigerant

 

R410a

Heating water range     

20 - 60℃

Cooling water range        

5  - 31℃

Compressor Type

 

GMCC\Panasonic

Ambient temp   

-25 ℃ - 43℃

Noise level(1 M)

dB(A)

≦55.0


The following boundary conditions must be kept:

The installation place should be selected in such a way that air intake and outlet is not hampered or obstructed leaves etc.

There should be provided sufficient space for intake and outlet as well as for operation and maintenance.

Air short-circuit must be avoided. The space necessary for intake and outlet must be always provided.

Intake air must be completely free from aggressive substances like ammonia, sulphur, chlorine etc.

The installation place should not be situated under living rooms or bedrooms because of sound emission and be placed at sufficient distance from the neighboring building.

It is not recommended to install the heat pump into wall niches(air short-circuit, sound echo)

The heat pump must not be installed in a trough(in the terrain or building)

Air intake and outlet

Take particular account of the sound emissions. Local prescriptions must be observed.

Condensate pipeline

Condensate must be able to run off freely(frost protected drain.).The condensate drain must be provided on-site with an air-tight siphon of minimum height 100mm.

Wall lead through

Wall lead through for pipelines must be implemented and sealed by technicians.

Electric connections

Electric connection cables must be short, connected flexibly and be mounted by technicians and according to local prescription.

Where trace heating tapes for the condensate drain and the flow and return lines are used, they must be connected externally in accordance with applicable regulations and additionally protected by a ground fault circuit interrupter.


Hot Tags: new looking inverter heat pump, China, suppliers, manufacturers, factory, customized, quotation, low price, made in China